NEW RESIDENTIAL BUILDINGS AND ADDITIONS
New Homes AND Additions
Complete submission includes:
- Building Permit Application
- Elevation Certificate if within a flood plain. (If you are unsure, please contact our office for the most recent FEMA information regarding your property)
- Declared occupancy use and type of construction
- 3 sets of Plans (2 full size large sets and 1 reduced size 11x17)
- Site Plan (1” = 20’)
- Floor Plan (1/4” = 1-0” min.)
- Foundation Plan—Sealed and signed by a Professional Engineer licensed by the State of Texas
- Exterior elevations—window sills, ceiling heights all types in all rooms, eave heights, exterior wall finishes
- Roof Plan and Type of roof cover
- Building Section—typical framing members and specifications and all ceiling heights including furr downs, slopes, and vaults
- ResCheck Compliance Certificate—Energy Code Compliance—For New Homes or Additions under 400 sqft, you can submit this form:The City of Corpus Christi Prescriptive Energy Form ( Residential Prescriptive Energy Form ) must be signed by the responsible party.
- ResCheck Compliance Certificate—Energy Code Compliance—For New Homes or Additions over 400 sqft, use the 2009 IECC Form created from ResCheck tools (www.energycodes.gov/rescheck/download.stm ) must be signed by the responsible party.
- Windstorm - Completed Texas Department of Insurance WPI-1 Form
www.tdi.state.tx.us/wind/dwnloads.html#eng-1 - Drawing(s) sealed and signed by a Professional Engineer licensed by the State of Texas showing:
- Hold down locations and capacities
- Uplift from plate to plate and top plate to rafter connections
- Shear transfer method
- Wall studs grade size and max. plate height
- Labeling of shear and load transferring walls, including detail of fastening methods
- Anchor bolt sizing and placement and/or method of anchoring to be used
- Details for non-prescriptive design and/or construction methods
- Wind load summary
- A statement that the engineer will maintain a permanent file containing the structural design information for all non-prescriptive components of the structure.
- Septic System Letter from Health Department if septic system is being used on property